I love FreeBSD. It's been my go-to OS since I first switched to it from BSDi many many years ago. However, I hate to stick with something just because I've always used it. Technology changes too quickly to make lifelong bonds. While I prefer FreeBSD, I ultimately will choose what gets the job done the best.
ZFS under FreeBSD has always progressed nicely, but it is obviously behind Solaris, seeing how Sum/Oracle are the creators of ZFS. The ZFS v28 patch is currently being tested for FreeBSD-8.2 and 9, but not released yet.
While I realize these are pre-releases, I wanted to test the performance I could expect from FreeBSD vs Solaris for my SAN that I'm building. Once I put this SAN into regular use, I won't easily be able to switch to another OS, or do a lot of tweaking with it.
This is not just a test of ZFS implementations - It tests the hard disk subsystem, memory, NFS, ethernet drivers, and ZFS to give me a combined test result, which is what I really care about - How fast can my SAN accept and serve up data to my ESXi boxes.
I've seperately been benchmarking FreeBSD 8.2-PRE and 9.0-CURRENT with both the v28 ZFS patch, and with their native v15 ZFS implementations. I'll make that a seperate blog entry a bit later on, but for now, I'm choosing the fastest performer from the v28 portion of those tests, which was FreeBSD 9.0-CURENT.
My test environment is as follows:
ESX Box: Dell PowerEdge T710 w/96Gig
SAN Box: Dell PowerEdge Y710 w/24Gig
Network: Intel X510DA2 10Gbe Ethernet in each box, direct attached
SAS Card: Areca 1880ix w/4G Cache
Enclosure: SuperMicro SC847-JBOD2 (Dual 6Gbps Backplanes)
Drives: Seagate 1.5 TB SATA, 5 disk raidz, no log or cache
Test Software: Performance Test 6.1 run on a Windows 2003 VM
Solaris 11 Express svn_151a
903 MBs - Fileserver
466 MBs - Webserver
53 MBs - Workstation
201 MBs - Database
FreeBSD-9.0 Current @ Dec 12th 2010 w/v28 Patch, all Debug off
95 MBs - Fileserver
60 MBs - Webserver
30 MBs - Workstation
32 MBs - Database
Wow. Notice the difference? I didn't believe it myself at first, but I tried it again and again, I watched the packet traffic accross the Intel card with iftop, and then I ran seperate benchmarks with iometer just to make sure it wasn't something silly in Performance Meter. I always received similar results - Solaris 11 Express can move some serious data in comparison to FreeBSD 9.0
At this stage, I don't know if it's a problem with the Intel driver holding back FreeBSD or not. You'll notice that the Workstation test is the only one that is compariable between FreeBSD and ZFS, which is made up of a lot of sync random read/writes that brings any ZFS implementation to it's knees.
The thing is: I don't care if it's the Intel driver, the memory sub-system, or whatever - In the end, I need the best performance delivered to my ESXi boxes, and Solaris 11 Express can deliver where FreeBSD isn't ready just yet.
I do fully expect FreeBSD to catch up, but for now, I'm strongly considering spendng the $$ on a Solaris 11 Express license so I can run it as my SAN OS. Solaris' easy CIFS implementation is another bonus for my SAN - it was delivering 78 MBs speeds when my FreeBSD/samba implementation was at 35MBs.
Reviews, rants, and misc thoughts on technology. I'm trying to give back to the internet community who's various blogs and forums have given me so much information in the past.
Sunday, January 9, 2011
Thursday, January 6, 2011
Areca 1880 Firmware v1.49 improves speed in Web Management, Solaris 11
I just applied the 1.49 firmware update for my Areca 1880, and the speed difference for user interface interaction is noticeable.
You'll have to download it from their Taiwan FTP site, which is listed on their support page.
The web console is now quite snappy, where before it was painful. In Solaris 11 Express, I'm able to list my 26+ drives without delay, where before it would take 5-10 seconds to give me a full drive inventory, which was leading to some serious delays in zpool status commands.
When applying your update via the web console, make sure to apply all 4 files individually. It's not smart, it won't ask for the other files, but it does need them if you want to be fully updated across the board.
I ran a set of iometer tests before and after my upgrade, and I can't detect any change in drive speed, just user interface speed.
You'll have to download it from their Taiwan FTP site, which is listed on their support page.
The web console is now quite snappy, where before it was painful. In Solaris 11 Express, I'm able to list my 26+ drives without delay, where before it would take 5-10 seconds to give me a full drive inventory, which was leading to some serious delays in zpool status commands.
When applying your update via the web console, make sure to apply all 4 files individually. It's not smart, it won't ask for the other files, but it does need them if you want to be fully updated across the board.
I ran a set of iometer tests before and after my upgrade, and I can't detect any change in drive speed, just user interface speed.
Tuesday, January 4, 2011
Partition Alignment with ESX and Windows 2003. Just do it.
You really want to make sure your partitions are aligned.
Partition Alignment, in a nutshell, is making sure your partitions start on Sector # 2048 (or some multiple of 512) instead of the standard Sector # 63.
There are some great blog entries that define the issue, so I won't get into it here.
While you don't need to do this for 2008 partitions (they start properly aligned), I've always known I should align my older 2003 partitions, but I haven't bothered. Today I decided to do a simple test to see the results of running un-aligned.
Test Details:
OS: Windows 2003 32bit
Test Package: Performance Test 6.1, running Webserver disk role benchmark
VM: ESXi 4.1
Drives: NFS share to a Solaris 11 ZFS box.
I chose the webserver role because it's a heavy reader (writes are harder to benchmark on ZFS), and because it's my worst performer. The other roles are hitting 900-1200 MB/sec, which is close to the max I can drive through my 10Gbe card.
That's a 30% increase in read speed. Wow, that's a lot of speed to throw away for not aligning a partition.
Here's a link to a quick little tool that will let you know within Windows if your partition is aligned: http://ctxadmtools.musumeci.com.ar/VMCheckAlign/VMCheckAlignment10.html
Of course, it can be a pain in the ass to align a partition. You can use a livecd of gparted, or create a new disk and partition it with Windows 2008, copying the data to the new partition from a seperate VM.
Some partition tools are now including the ability to quickly and easily specify a aligned-partition start, so hopefully this will be an easy task in the near future. If you know the name of any easy booting GUI type partition tools that can move a Windows partition to sector 2048 without much fuss, please let me know and I'll post it here.
I personally do it with gparted live, but I'm also not affraid of the command line. Something easier would be nice.
Partition Alignment, in a nutshell, is making sure your partitions start on Sector # 2048 (or some multiple of 512) instead of the standard Sector # 63.
There are some great blog entries that define the issue, so I won't get into it here.
While you don't need to do this for 2008 partitions (they start properly aligned), I've always known I should align my older 2003 partitions, but I haven't bothered. Today I decided to do a simple test to see the results of running un-aligned.
Test Details:
OS: Windows 2003 32bit
Test Package: Performance Test 6.1, running Webserver disk role benchmark
VM: ESXi 4.1
Drives: NFS share to a Solaris 11 ZFS box.
I chose the webserver role because it's a heavy reader (writes are harder to benchmark on ZFS), and because it's my worst performer. The other roles are hitting 900-1200 MB/sec, which is close to the max I can drive through my 10Gbe card.
Aligned Partition: 609 MB/sec
Non-Aligned Partition: 436 MB/sec
That's a 30% increase in read speed. Wow, that's a lot of speed to throw away for not aligning a partition.
Here's a link to a quick little tool that will let you know within Windows if your partition is aligned: http://ctxadmtools.musumeci.com.ar/VMCheckAlign/VMCheckAlignment10.html
Of course, it can be a pain in the ass to align a partition. You can use a livecd of gparted, or create a new disk and partition it with Windows 2008, copying the data to the new partition from a seperate VM.
Some partition tools are now including the ability to quickly and easily specify a aligned-partition start, so hopefully this will be an easy task in the near future. If you know the name of any easy booting GUI type partition tools that can move a Windows partition to sector 2048 without much fuss, please let me know and I'll post it here.
I personally do it with gparted live, but I'm also not affraid of the command line. Something easier would be nice.
Friday, December 31, 2010
OpenBSD 4.8 vs FreeBSD 8.1 em0 Network Performance
As mentioned in one of my earlier postings, I have been looking into OpenBSD as a possible firewall OS.
I'll post a more opinion-based article shortly on what I think about OpenBSD vs FreeBSD, but for now, I thought I'd report this tidbit of info;
When benchmarking with netperf, OpenBSD 4.8 wasn't as fast as FreeBSD 8.1 until I tweaked some sysctls.
OpenBSD 4.8 - 520.49 Mbits/sec
FreeBSD 8.1 - 941.49 Mbits/sec
I then applied the speed tweaks for OpenBSD found here: https://calomel.org/network_performance.htm , and then was able to match FreeBSD's performance using NetPerf.
While this was with the em driver (Intel), I believe it would show on other drivers as well, as the sysctl's adjusted weren't specific to the em driver.
Conclusion? Make sure you're applying these tuning tips if you're running OpenBSD 4.8
I'll post a more opinion-based article shortly on what I think about OpenBSD vs FreeBSD, but for now, I thought I'd report this tidbit of info;
When benchmarking with netperf, OpenBSD 4.8 wasn't as fast as FreeBSD 8.1 until I tweaked some sysctls.
OpenBSD 4.8 - 520.49 Mbits/sec
FreeBSD 8.1 - 941.49 Mbits/sec
I then applied the speed tweaks for OpenBSD found here: https://calomel.org/network_performance.htm , and then was able to match FreeBSD's performance using NetPerf.
While this was with the em driver (Intel), I believe it would show on other drivers as well, as the sysctl's adjusted weren't specific to the em driver.
Conclusion? Make sure you're applying these tuning tips if you're running OpenBSD 4.8
Friday, December 17, 2010
Building a Ghetto-SAN - Part 1 - Basic Considerations
What is a Ghetto-SAN?
It's a SAN built on the cheap with whatever you can get your hands on.
In my situation, it's not sacrificing any type of reliability or speed, it's simply putting together a lot of parts that may not typically exist in enterprise SAN deployments.
I built a 6 TB FreeBSD/Samba server roughly two years ago when 1.5 TB drives first came out, but we've long since outgrown that. I could build another 12 TB easily enough, but that may not last me the year, and I don't want to start piling more servers around the office. I need consolidation as well as massive storage.
I project that we need at least 24 TB to make it two more years, and 36 TB may be preferable. Some of my data recovery projects are chewing up 3-5 TB and the complex ones involving law firms as clients sometimes mean I need to hold on to that data for 3 months before I can delete it.
I need a SAN, but I can't afford even the "affordable" SAN's from EMC, EqualLogic, etc. These things start at $100k for the features and storage density that I need today.
So I decided to build my own, basing it on opensource software (thanks guys!), ZFS, SATA drives, and whatever else I needed to make this thing the foundation of our little data centre. I'm flip-flopping on FreeBSD/Solaris/Nexenta as my SAN OS, but that's another topic.
It's been over 6 months since I started building and testing the environment, and I've learned a lot. This is not a task for the faint-at-heart, nor for those who don't like to do a lot of testing.
I plan on posting more information about what I've learned, my SAN specs, etc. over the next few months, but first I wanted to quickly comment on what I feel are two dead-end paths for some people trying to design their own Ghetto-SAN's.
Mistake #1 - Getting hung up with Controller/Disk bandwidth when you don't have the network for it
You need to realize that a 6 drive FreeBSD/ZFS raidz on a 3 year old Core 2 system with Intel's ICH 7 drive chipset, and 4 gig of RAM can saturate a 1 Gb network port - At least mine could.
This was my test bench for early SAN performance stats. It's when I knew I needed to look into faster network performance (and I eventually settled on 10 Gb Ethernet over FiberChannel and InfiniBand. That's also another post.)
If you're not talking about a 10Gbe network as the backbone for your SAN, don't worry about your drive performance. There's no need to buy seperate SAS controllers, SAS drives, and make sure everything is connected end-to-end.
Just get a simple SAS HBA for ~$200, hook it into a SAS backplane (and the old 3.0 Gb/sec ones are dropping nicely in price now) and you're going to be able to run that 1 Gb network port into the ground... and it will probably be faster than a basic 4 drive RAID-10 Direct Attached Storage (DAS) for a lot of things, thanks to ZFS having a great caching system. It beats the hell out of a PERC6 or H700 4 drive RAID-10 with 300 gig 6.0 Gb/sec SAS drives. You do have more latency, but the throughput is at least double in my tests, which well makes up for the 100 ms access time. Every VM i've moved to my test SAN has performed better, and "felt" better than the DAS units.
So you have 2 1 Gbe pots that you're going to team? Same story, I bet you'll be running ethernet into the ground before your disks are starving for I/O.
With 4 Ethernet ports, you may have cause - but you still need to do some testing. I decided on a single SAS 6.0 Gb/s HBA and SAS 6.0 Gb/s backplane for my SAN, and it's working out great for me.
Mistake #2 - Putting all your eggs in one basket
Everything fails. Everything.
If you have just one of anything that you depend on, you need to go read that last line again. I've got over 20 years experience in IT, and trust me when I say that the only thing you can count on with technology is it's eventual failure.
I have dual everything in my data centre. Dual UPS's connected to dual battery banks, feeding dual PDU's to the servers that all have dual power supplies, so each server is fed from two UPS' in case one of them fails under load when the power cuts out and the generator hasn't started yet. Dual firewalls, dual ESX servers, etc. You get the picture.
Same for your SAN. It's far better to have two cheaper SAN boxes than one more expensive one.
I've gone with a fairly expensive Primary SAN (redundant back planes, power, network, etc). It will be my main go-to box, and will deliver the day-to-day performance that I need to stay sane.
I will also have a Secondary SAN that will be run off an older server that will save my ass if the primary goes down. It won't be very fast at all, will be tight on storage, and low on RAM - BUT it will hold a copy of all my critical data, and a very recent snapshot backup of the main critical servers so I can get my network up and running within 15 minutes in case of failure in the main SAN.
This is completely redundant hardware, done on the cheap - and you need something like this if you care about your data. I just need to stuff more drives into an old case, setup some zfs send/recv and snapshot jobs, and I'm done.
I'm currently lucky - Not losing data is my primary concern. Quick repair is my second, but my clients will tolerate a rare incident that may result in their data access being interrupted for 30 minutes, followed by a day of slow service until we get the primary back on-line. Not everyone may be that lucky, so make sure you take the worst-case scenario into account when you start designing your SAN.
--
I hope to followup on this more regularly as my SAN timidly transitions from testing into full production. Comments and opinions welcome.
It's a SAN built on the cheap with whatever you can get your hands on.
In my situation, it's not sacrificing any type of reliability or speed, it's simply putting together a lot of parts that may not typically exist in enterprise SAN deployments.
I built a 6 TB FreeBSD/Samba server roughly two years ago when 1.5 TB drives first came out, but we've long since outgrown that. I could build another 12 TB easily enough, but that may not last me the year, and I don't want to start piling more servers around the office. I need consolidation as well as massive storage.
I project that we need at least 24 TB to make it two more years, and 36 TB may be preferable. Some of my data recovery projects are chewing up 3-5 TB and the complex ones involving law firms as clients sometimes mean I need to hold on to that data for 3 months before I can delete it.
I need a SAN, but I can't afford even the "affordable" SAN's from EMC, EqualLogic, etc. These things start at $100k for the features and storage density that I need today.
So I decided to build my own, basing it on opensource software (thanks guys!), ZFS, SATA drives, and whatever else I needed to make this thing the foundation of our little data centre. I'm flip-flopping on FreeBSD/Solaris/Nexenta as my SAN OS, but that's another topic.
It's been over 6 months since I started building and testing the environment, and I've learned a lot. This is not a task for the faint-at-heart, nor for those who don't like to do a lot of testing.
I plan on posting more information about what I've learned, my SAN specs, etc. over the next few months, but first I wanted to quickly comment on what I feel are two dead-end paths for some people trying to design their own Ghetto-SAN's.
Mistake #1 - Getting hung up with Controller/Disk bandwidth when you don't have the network for it
You need to realize that a 6 drive FreeBSD/ZFS raidz on a 3 year old Core 2 system with Intel's ICH 7 drive chipset, and 4 gig of RAM can saturate a 1 Gb network port - At least mine could.
This was my test bench for early SAN performance stats. It's when I knew I needed to look into faster network performance (and I eventually settled on 10 Gb Ethernet over FiberChannel and InfiniBand. That's also another post.)
If you're not talking about a 10Gbe network as the backbone for your SAN, don't worry about your drive performance. There's no need to buy seperate SAS controllers, SAS drives, and make sure everything is connected end-to-end.
Just get a simple SAS HBA for ~$200, hook it into a SAS backplane (and the old 3.0 Gb/sec ones are dropping nicely in price now) and you're going to be able to run that 1 Gb network port into the ground... and it will probably be faster than a basic 4 drive RAID-10 Direct Attached Storage (DAS) for a lot of things, thanks to ZFS having a great caching system. It beats the hell out of a PERC6 or H700 4 drive RAID-10 with 300 gig 6.0 Gb/sec SAS drives. You do have more latency, but the throughput is at least double in my tests, which well makes up for the 100 ms access time. Every VM i've moved to my test SAN has performed better, and "felt" better than the DAS units.
So you have 2 1 Gbe pots that you're going to team? Same story, I bet you'll be running ethernet into the ground before your disks are starving for I/O.
With 4 Ethernet ports, you may have cause - but you still need to do some testing. I decided on a single SAS 6.0 Gb/s HBA and SAS 6.0 Gb/s backplane for my SAN, and it's working out great for me.
Mistake #2 - Putting all your eggs in one basket
Everything fails. Everything.
If you have just one of anything that you depend on, you need to go read that last line again. I've got over 20 years experience in IT, and trust me when I say that the only thing you can count on with technology is it's eventual failure.
I have dual everything in my data centre. Dual UPS's connected to dual battery banks, feeding dual PDU's to the servers that all have dual power supplies, so each server is fed from two UPS' in case one of them fails under load when the power cuts out and the generator hasn't started yet. Dual firewalls, dual ESX servers, etc. You get the picture.
Same for your SAN. It's far better to have two cheaper SAN boxes than one more expensive one.
I've gone with a fairly expensive Primary SAN (redundant back planes, power, network, etc). It will be my main go-to box, and will deliver the day-to-day performance that I need to stay sane.
I will also have a Secondary SAN that will be run off an older server that will save my ass if the primary goes down. It won't be very fast at all, will be tight on storage, and low on RAM - BUT it will hold a copy of all my critical data, and a very recent snapshot backup of the main critical servers so I can get my network up and running within 15 minutes in case of failure in the main SAN.
This is completely redundant hardware, done on the cheap - and you need something like this if you care about your data. I just need to stuff more drives into an old case, setup some zfs send/recv and snapshot jobs, and I'm done.
I'm currently lucky - Not losing data is my primary concern. Quick repair is my second, but my clients will tolerate a rare incident that may result in their data access being interrupted for 30 minutes, followed by a day of slow service until we get the primary back on-line. Not everyone may be that lucky, so make sure you take the worst-case scenario into account when you start designing your SAN.
--
I hope to followup on this more regularly as my SAN timidly transitions from testing into full production. Comments and opinions welcome.
Intel X520 DA 10 Gbe Network Card and FreeBSD 8.2-PRE and 9.0-Current
I love my Intel X520 DA. It's two SPF+ 10 Gbe Network ports on one PCIe 4x card.
Out of the box, it works great with FreeBSD 8.1, even if you ignore Intel's optimization advice.
Currently for $380 a card (Retail close to $500), it's part of my Ghetto-SAN foundation. No need for an expensive 10 Gbe switch when you can afford to put two of these in each machine and make a simple point-to-point SAN network.
However, under FreeBSD 8.2-PRE and 9.0-CURRENT (both are not official releases yet) it won't work properly if you set the card to a MTU of 9000 or higher.
The reason is that it runs out of buffers to handle traffic of that size.
The quick fix is to put these settings into your /etc/sysctl.conf
The kicker is the last line - nmbjumbo9 - By default FreeBSD allocates 6400, which isn't enough to handle what this card can produce. This isn't some little 100 Mbit card.. that's 10,000 Mbit that it needs to push. Expect to require deep buffers.
Remember to check your netstat -m output to see if you are close to exhaustion with nmbjumbo9 at 48000 - Mine was using ~36000 after some load testing.
Here's some additional information on settings for the card, and drivers, etc.
http://www.intel.com/support/network/sb/CS-025829.htm
http://downloadcenter.intel.com/SearchResult.aspx?lang=eng&ProductFamily=Network+Connectivity&ProductLine=Intel%C2%AE+Server+Adapters&ProductProduct=Intel%C2%AE+Ethernet+Server+Adapter+X520+Series
Out of the box, it works great with FreeBSD 8.1, even if you ignore Intel's optimization advice.
Currently for $380 a card (Retail close to $500), it's part of my Ghetto-SAN foundation. No need for an expensive 10 Gbe switch when you can afford to put two of these in each machine and make a simple point-to-point SAN network.
However, under FreeBSD 8.2-PRE and 9.0-CURRENT (both are not official releases yet) it won't work properly if you set the card to a MTU of 9000 or higher.
The reason is that it runs out of buffers to handle traffic of that size.
The quick fix is to put these settings into your /etc/sysctl.conf
hw.intr_storm_threshold=9000
kern.ipc.nmbclusters=262144
kern.ipc.nmbjumbop=262144
kern.ipc.nmbclusters=262144
kern.ipc.nmbjumbop=262144
kern.ipc.nmbjumbo9=48000
The kicker is the last line - nmbjumbo9 - By default FreeBSD allocates 6400, which isn't enough to handle what this card can produce. This isn't some little 100 Mbit card.. that's 10,000 Mbit that it needs to push. Expect to require deep buffers.
Remember to check your netstat -m output to see if you are close to exhaustion with nmbjumbo9 at 48000 - Mine was using ~36000 after some load testing.
Here's some additional information on settings for the card, and drivers, etc.
http://www.intel.com/support/network/sb/CS-025829.htm
http://downloadcenter.intel.com/SearchResult.aspx?lang=eng&ProductFamily=Network+Connectivity&ProductLine=Intel%C2%AE+Server+Adapters&ProductProduct=Intel%C2%AE+Ethernet+Server+Adapter+X520+Series
Wednesday, December 15, 2010
lagg performance penalty between ESXi 4.1 and FreeBSD 8.1
While doing some benchmarks of my ZFS/NFS/ESX setups, I started fiddling with the lagg driver to create a fail-over connection between my ESX server and the ZFS server.
Both boxes have the Intel x520DA 10Gbe adapter, which has 2 10 Gig ports.
ESXi doesn't offer proper load-balance between two ports unless you get into the Cisco Nexus vswitch, which I currently don't have.
I ran a few quick tests with my usual 2003 32 Bit VM and Performance test 6.1, and here's what I found;
Both boxes have the Intel x520DA 10Gbe adapter, which has 2 10 Gig ports.
ESXi doesn't offer proper load-balance between two ports unless you get into the Cisco Nexus vswitch, which I currently don't have.
I ran a few quick tests with my usual 2003 32 Bit VM and Performance test 6.1, and here's what I found;
Type of Test With lagg Without lagg % Diff
File Server: 478.16 491 2.6
Webserver: 84.19 86.46 2.6
Workstation: 0.52 0.6 13
Database: 127.88 136.15 6
Every test was slower with lagg being used.
This is something interesting to think about, as a lot of admins enable lagg or similar failover technology without thinking that there may be a performance impact.
At this stage, I don't know if it's on the lagg side, or ESX's side - I'd have to run further tests. I'll add it to the list of things that I'd like to know if I had time.
But for now, I know that I'll take a small performance hit to have this fail-over setup.
Sunday, December 5, 2010
Netperf and SMP - Oddness (Part 2 of 2)
To continue my previous post.. http://christopher-technicalmusings.blogspot.com/2010/12/netperf-and-smp-oddness.html
I was concerned that the poor performance of netperf when it was run on a multi-processor system was due to SMP overhead.
The only way to know for sure would be to run the test with netperf and netserver on separate (but identical) machines. That way I could ensure data was transferring across the network cable, and not being accelerated by any buffer-copy process within the processors or system.
I once again setup my netperf and netserver test, using FreeBSD 8.1 AMD64 on two Dell PowerEge 1950's.
In one set of tests, I restricted both ends to use a single CPU. In the other I let the system choose what CPU to run on (which results in the process jumping CPU a number of times as it executes the threads on the most opportunistic CPU - as noted with top -P).
The command was;
netperf -H 192.168.88.1 -L 192.168.88.2 -t TCP_STREAM -l 300 -f m
The results show no difference between multi-processor and single processor results. In either test, I saw 941.49 Megabits/sec, regardless of single or multiple CPU's.
Which means that there are some serious optimizations for working between 2 network cards in the same physical machine, as seen in my previous tests. The same tests run from one internal NIC to the other result in 4500 - 9000 MBits/sec depending on if it's all through one CPU or across multiple CPU's.
I obviously need to spend more time understanding this, as it would make a large difference when you're considering a firewall application, or anything that needs to move a lot of data between interfaces.
I welcome any insights..
I was concerned that the poor performance of netperf when it was run on a multi-processor system was due to SMP overhead.
The only way to know for sure would be to run the test with netperf and netserver on separate (but identical) machines. That way I could ensure data was transferring across the network cable, and not being accelerated by any buffer-copy process within the processors or system.
I once again setup my netperf and netserver test, using FreeBSD 8.1 AMD64 on two Dell PowerEge 1950's.
In one set of tests, I restricted both ends to use a single CPU. In the other I let the system choose what CPU to run on (which results in the process jumping CPU a number of times as it executes the threads on the most opportunistic CPU - as noted with top -P).
The command was;
netperf -H 192.168.88.1 -L 192.168.88.2 -t TCP_STREAM -l 300 -f m
The results show no difference between multi-processor and single processor results. In either test, I saw 941.49 Megabits/sec, regardless of single or multiple CPU's.
Which means that there are some serious optimizations for working between 2 network cards in the same physical machine, as seen in my previous tests. The same tests run from one internal NIC to the other result in 4500 - 9000 MBits/sec depending on if it's all through one CPU or across multiple CPU's.
I obviously need to spend more time understanding this, as it would make a large difference when you're considering a firewall application, or anything that needs to move a lot of data between interfaces.
I welcome any insights..
Danger with Dell's H700 RAID card and FreeBSD 8.1-9.0
My new Dell PowerEdge T710 came with a fairly decent Dell PERC RAID card - the H700 with 512M of battery backed cache. It's a LSI 2108 based solution, and was providing far better performance than their older PERC5 or PERC6 solutions. It is even 6.0 G/s.
However - It's still a Dell RAID card, which are known for their slow speed. What do you expect, they need to protect their profit margins. :-)
Slow speed was something I was prepared to deal with - but that wasn't my issue; Specifically, I could never get a stable system using the mirrors I made with the H700.
It would be between a day or a few hours, and I'd start to see device timeout errors popping up on the console for one of the RAID mirror devices. I knew something was up, because my NFS connection to this box would die.
Oddly enough, the FreeBSD system was up, responsive, and I could browse the directories. I could not for the life of me get ESX to see my NFS shares on this box anymore. It didn't matter what services I restarted, it was down.
A reboot, and everything would be fine, until the next set of errors on the console. Very frustrating as you can imagine.
After some research, I've found that the LSI drivers are not the best in FreeBSD due to corporate disclosure issues. I found this to be a shame, as I've loved LSI products for years in a Windows environment, and have even used their older chipsets without issue in FreeBSD as well.
If LSI would work with the open source community a bit more, maybe we'd be have a stable driver for it. At this stage, I'd say it's not a good idea in a production FreeBSD box.
So I needed a new brand to depend on, and this time around I was going to choose a company that had solid FreeBSD support.
Research returned good opinions about the Areca brand controllers. Not only are they often on the top of the benchmarks between other brands of RAID card, but they have native FreeBSD drivers - Source or compiled kernel lodable.
I dove in a purchased an Areca1880ix-12, shown below.
It may be a bit of overkill, but this thing can be expanded to 4 gig of RAM, has a dedicated RJ-45 port in the back for full web management, and it's currently on the top of the SAS 6.0 RAID HBA speed charts.
I also really like the 4 SAS 6.0 ports. I'll explain why in a future blog article when I detail my SAN build.
After a month of running this card, I've yet to have an odd panic, disk issue, or other crash with my SAN. It's rock solid with no complaints.
It's been so long, that I don't even have the logs of the original error message that the H700 would throw.. sorry.. but you'll see it if you hook one up with FreeBSD. :-)
If anyone gets a H700 running cleanly with a RAID mirror, let me know. I still have my H700, it's destined for ebay or possibly a spare for a Windows only box.
However - It's still a Dell RAID card, which are known for their slow speed. What do you expect, they need to protect their profit margins. :-)
Slow speed was something I was prepared to deal with - but that wasn't my issue; Specifically, I could never get a stable system using the mirrors I made with the H700.
It would be between a day or a few hours, and I'd start to see device timeout errors popping up on the console for one of the RAID mirror devices. I knew something was up, because my NFS connection to this box would die.
Oddly enough, the FreeBSD system was up, responsive, and I could browse the directories. I could not for the life of me get ESX to see my NFS shares on this box anymore. It didn't matter what services I restarted, it was down.
A reboot, and everything would be fine, until the next set of errors on the console. Very frustrating as you can imagine.
After some research, I've found that the LSI drivers are not the best in FreeBSD due to corporate disclosure issues. I found this to be a shame, as I've loved LSI products for years in a Windows environment, and have even used their older chipsets without issue in FreeBSD as well.
If LSI would work with the open source community a bit more, maybe we'd be have a stable driver for it. At this stage, I'd say it's not a good idea in a production FreeBSD box.
So I needed a new brand to depend on, and this time around I was going to choose a company that had solid FreeBSD support.
Research returned good opinions about the Areca brand controllers. Not only are they often on the top of the benchmarks between other brands of RAID card, but they have native FreeBSD drivers - Source or compiled kernel lodable.
I dove in a purchased an Areca1880ix-12, shown below.
It may be a bit of overkill, but this thing can be expanded to 4 gig of RAM, has a dedicated RJ-45 port in the back for full web management, and it's currently on the top of the SAS 6.0 RAID HBA speed charts.
I also really like the 4 SAS 6.0 ports. I'll explain why in a future blog article when I detail my SAN build.
After a month of running this card, I've yet to have an odd panic, disk issue, or other crash with my SAN. It's rock solid with no complaints.
It's been so long, that I don't even have the logs of the original error message that the H700 would throw.. sorry.. but you'll see it if you hook one up with FreeBSD. :-)
If anyone gets a H700 running cleanly with a RAID mirror, let me know. I still have my H700, it's destined for ebay or possibly a spare for a Windows only box.
Friday, December 3, 2010
Netperf and SMP - Oddness (Part 1 of 2)
Netperf seems to still be a fairly standard network performance tool. I see iperf out there as well, and interestingly enough, it generates very different numbers from netperf.
I've decided to go with netperf for my benchmarking needs, and have started running some simple tests with it to become more familiar with it's operation.
The first oddness I notice is with SMP. I get wildly different results depending on if multiple CPU's are used.
Let's start with what I'm running on: FreeBSD 8.1 AMD64 on a Dell 1850 PowerEdge, with 2 Xeon 5340 CPU. These machines have 2 Intel 1000MT NICs built into the board, which I have given 192.168.88.1 and 192.68.88.2 to. They run the em0 driver. I've connected them together with a cross-over cable.
FreeBSD is setup as stock, installed from the CD, no changes.
I'm using cpuset to drive the applications to one CPU or the other. Here's what I'm executing;
By specifying the different IP's, I'm forcing the data to move from one NIC to the other. It's running IPv4, not IPv6.
This combination drives both the receive server (netserver) and the test program (netperf) from the same CPU. If I want to make them run on different CPU's I'd change one of the -l 0's to -l 1. If I want to leave it up to the kernel to schedule, I leave out the cpuset command entirely.
All hyperthreading is turned off. These are two standalone CPU's.
Here's what I'm getting, expressed in GigaBytes per Sec
Same CPU: 1.05 GB/sec
Very interesting..
We're looking at 1/2 speed when we run it on different CPU's. When we don't set a preference for the CPU, it will flip-flop between the two, sometimes both on one, other times separate. The speed for the no preference is almost exactly a split of the single CPU and dual CPU speeds.
I've researched this online, and found a few other people mentioning similar issues, but the threads never come to a conclusion.
There are two reasons I can think of this wide spread between single and dual CPU speeds;
1) Because all the work is happening on one CPU, there is some sort of cache/memory/buffer combining that allows for a faster transfer of data on the PCI bus. Maybe the data isn't transferring - but I do see the little link lights blinking away furiously when I run the tests.
2) There is significant overhead between the processors for SMP.
I do have a second identical PowerEdge 1850 that I plan on bringing into this equation shortly to try and figure out where this is coming from. By sending to a separate machine, I'm going to eliminate the possibility that the CPU is combining something.
However, if you're looking to make a firewall run quickly, it looks at from this first small test that a single CPU firewall will outperform a dual. That's an early conclusion, and I'll post more shortly when I know more.
If anyone has more info on this, that would be great.
Continued here..
http://christopher-technicalmusings.blogspot.com/2010/12/netperf-and-smp-oddness-part-1-of-2.html
I've decided to go with netperf for my benchmarking needs, and have started running some simple tests with it to become more familiar with it's operation.
The first oddness I notice is with SMP. I get wildly different results depending on if multiple CPU's are used.
Let's start with what I'm running on: FreeBSD 8.1 AMD64 on a Dell 1850 PowerEdge, with 2 Xeon 5340 CPU. These machines have 2 Intel 1000MT NICs built into the board, which I have given 192.168.88.1 and 192.68.88.2 to. They run the em0 driver. I've connected them together with a cross-over cable.
FreeBSD is setup as stock, installed from the CD, no changes.
I'm using cpuset to drive the applications to one CPU or the other. Here's what I'm executing;
cpuset -c -l 0 netserver -L 192.168.88.1 -n 2
cpuset -c -l 0 netperf -H 192.168.88.1 -L 192.168.88.2 -t TCP_STREAM -l 300
cpuset -c -l 0 netperf -H 192.168.88.1 -L 192.168.88.2 -t TCP_STREAM -l 300
By specifying the different IP's, I'm forcing the data to move from one NIC to the other. It's running IPv4, not IPv6.
This combination drives both the receive server (netserver) and the test program (netperf) from the same CPU. If I want to make them run on different CPU's I'd change one of the -l 0's to -l 1. If I want to leave it up to the kernel to schedule, I leave out the cpuset command entirely.
All hyperthreading is turned off. These are two standalone CPU's.
Here's what I'm getting, expressed in GigaBytes per Sec
Same CPU: 1.05 GB/sec
Different CPU: 0.47 GB/sec
No Preference: 0.88 GB/sec.
Very interesting..
We're looking at 1/2 speed when we run it on different CPU's. When we don't set a preference for the CPU, it will flip-flop between the two, sometimes both on one, other times separate. The speed for the no preference is almost exactly a split of the single CPU and dual CPU speeds.
I've researched this online, and found a few other people mentioning similar issues, but the threads never come to a conclusion.
There are two reasons I can think of this wide spread between single and dual CPU speeds;
1) Because all the work is happening on one CPU, there is some sort of cache/memory/buffer combining that allows for a faster transfer of data on the PCI bus. Maybe the data isn't transferring - but I do see the little link lights blinking away furiously when I run the tests.
2) There is significant overhead between the processors for SMP.
I do have a second identical PowerEdge 1850 that I plan on bringing into this equation shortly to try and figure out where this is coming from. By sending to a separate machine, I'm going to eliminate the possibility that the CPU is combining something.
However, if you're looking to make a firewall run quickly, it looks at from this first small test that a single CPU firewall will outperform a dual. That's an early conclusion, and I'll post more shortly when I know more.
If anyone has more info on this, that would be great.
Continued here..
http://christopher-technicalmusings.blogspot.com/2010/12/netperf-and-smp-oddness-part-1-of-2.html